Hardware Failure Alarm

This alarm is applicable only to Mediant 1000.

acHwFailureAlarm

Alarm

acHwFailureAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.43

Description

The alarm is sent when the device detects a hardware failure (faulty module or port) on an analog module (FXS or FXO).

Default Severity

Critical

Source Varbind Text

Chassis#0/module#<m>, where m is the module’s number

Event Type

equipmentAlarm

Probable Cause

equipmentMalfunction

Severity

Condition

Text

Corrective Action

Critical

The module is faulty or has been removed incorrectly.

"Module Alarm:  Faulty IF-Module"

Restart the device to clear this alarm. The alarm is not cleared.

Major

Module mismatch - module and CPU board mismatch.

"IF-Module Mismatch"

Restart the device to clear this alarm. The alarm is not cleared.