Hardware Failure Alarm
This alarm is applicable only to Mediant 1000.
acHwFailureAlarm
Alarm |
acHwFailureAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.43 |
||
Description |
The alarm is sent when the device detects a hardware failure (faulty module or port) on an analog module (FXS or FXO). |
||
Default Severity |
Critical |
||
Source Varbind Text |
Chassis#0/module#<m>, where m is the module’s number |
||
Event Type |
equipmentAlarm |
||
Probable Cause |
equipmentMalfunction |
||
Severity |
Condition |
Text |
Corrective Action |
Critical |
The module is faulty or has been removed incorrectly. |
"Module Alarm: Faulty IF-Module" |
Restart the device to clear this alarm. The alarm is not cleared. |
Major |
Module mismatch - module and CPU board mismatch. |
"IF-Module Mismatch" |
Restart the device to clear this alarm. The alarm is not cleared. |